Neuroimaging: Difference between revisions

From Citizendium
Jump to navigation Jump to search
imported>Johannes Reinhard
imported>Johannes Reinhard
No edit summary
Line 4: Line 4:
= Neuroimaging techniques =
= Neuroimaging techniques =


The aim of neuroimaging methods is to produce images of the brain. The two major fields are structural and functional imaging. Many different methods are used for this purpose, including
The aim of neuroimaging methods is to produce images of the brain or to visualize brain activity. The two major fields are structural and functional imaging. Many different methods are used for this purpose, including


* Electroencephalography (EEG)
* Electroencephalography (EEG)
Line 10: Line 10:
* Positron emission tomography (PET)
* Positron emission tomography (PET)
* Magnetic resonance imaging (MRI)
* Magnetic resonance imaging (MRI)
= Structural neuroimaging =
== MRI ==
Protons (<math>H^+</math>)are particles with spin <math>\frac {1}{2}</math>. In a strong external magnetic field <math>{\vec B}_0</math> they tend to line up with the field. The underlying effects can strictly be described only by the means of quantum mechanics. Nevertheless it is possible to imagine the mechanism via classical analogies.
The protons can be compared to a classical solid top. When a rotating solid top in a homogeneous gravitational field is not perfectly aligned with the vertical axis of the field, it starts a precession movement around this axis. Similarly the proton spins are preceding in the magnetic field with a characteristic frequency&mdash;the lamour frequency.
It is now possible to excite the proton spins by a RF pulse. Excited spins are not aligned with the external field any more, but are preceding in the xy-plane in a coherent way. This precession movement induces a measurable signal in a detection coil. When the RF pulse is stopped, 2 decay processes begin and the corresponding decay times are measured.
* Spin-lattice-relaxation (<math>T_1</math>), longitudinal relaxation: The spins realign with the external field.
* Spin-spin-relaxation (<math>T_2</math>), transverse relaxation: The spins precession movement is dephased and becomes incoherent.
Different types of tissue have influence on these relaxation times, producing contrast in pictures of different tissue.
Tomographic 3D-information is gathered by coding spatial information in gradient fields. These are overlayed on the external field and thereby modify the lamour frequency.


= Functional neuroimaging =
= Functional neuroimaging =

Revision as of 15:31, 1 September 2008

This article is developing and not approved.
Main Article
Discussion
Related Articles  [?]
Bibliography  [?]
External Links  [?]
Citable Version  [?]
Video [?]
 
This editable Main Article is under development and subject to a disclaimer.
Nuvola apps kbounce green.png
Nuvola apps kbounce green.png
This article is currently being developed as part of an Eduzendium student project. The project's homepage is at CZ:Guidel 2008 summer course on Music and Brain‎. One of the goals of the course is to provide students with insider experience in collaborative educational projects, and so you are warmly invited to join in here, or to leave comments on the discussion page. However, please refrain from removing this notice.
Besides, many other Eduzendium articles welcome your collaboration!



Neuroimaging techniques

The aim of neuroimaging methods is to produce images of the brain or to visualize brain activity. The two major fields are structural and functional imaging. Many different methods are used for this purpose, including

  • Electroencephalography (EEG)
  • Magnetoencephalography (MEG)
  • Positron emission tomography (PET)
  • Magnetic resonance imaging (MRI)

Structural neuroimaging

MRI

Protons ()are particles with spin . In a strong external magnetic field they tend to line up with the field. The underlying effects can strictly be described only by the means of quantum mechanics. Nevertheless it is possible to imagine the mechanism via classical analogies.

The protons can be compared to a classical solid top. When a rotating solid top in a homogeneous gravitational field is not perfectly aligned with the vertical axis of the field, it starts a precession movement around this axis. Similarly the proton spins are preceding in the magnetic field with a characteristic frequency—the lamour frequency.

It is now possible to excite the proton spins by a RF pulse. Excited spins are not aligned with the external field any more, but are preceding in the xy-plane in a coherent way. This precession movement induces a measurable signal in a detection coil. When the RF pulse is stopped, 2 decay processes begin and the corresponding decay times are measured.

  • Spin-lattice-relaxation (), longitudinal relaxation: The spins realign with the external field.
  • Spin-spin-relaxation (), transverse relaxation: The spins precession movement is dephased and becomes incoherent.

Different types of tissue have influence on these relaxation times, producing contrast in pictures of different tissue.

Tomographic 3D-information is gathered by coding spatial information in gradient fields. These are overlayed on the external field and thereby modify the lamour frequency.

Functional neuroimaging

Functional neuroimaging is used to image metabolic activity in neural tissue.

Positron emission tomography

Radioactive labels are injected into the human body. In their decay they emit gamma-rays. These are measured and the source is localized by tomographic reconstruction.

Functional MRI (fMRI)

Active regions in neural tissue need a high oxygen supply. When a region gets the body provides it with more oxygenated blood. Because of the different magnetic susceptibility of oxygenated and deoxygenated blood this can be made visible by MRI methods. This technique is called blood-oxygen level dependent (BOLD) fMRI. It is often used in research to measure the reaction of the brain to certain stimuli or actions.

Data processing issues

Data provenance

To be useful as data resource in scientific collaborations, the history of images has to be tracked. This is called "provenance" (also "lineage" or "pedigree"). Provenance consists of the data part and the process part. The data provenance contains information about the origin of raw images, while the process provenance documents the way those images have been manipulated.

Measuring the Brain structure

Voxel-Based morphometry

Diffusion-tensor MRI

By applying a gradient to the magnetic field the diffusion of water can be imaged. To get 3D diffusion information a series of measurements with different gradient directions has to be performed.

Generating Brain atlases